Specifications |
|
Maximum voltage between any terminal and
earth ground |
|
|
Surge protection |
| |
6 kV
peak per IEC 61010-1 600 VCAT
III, Pollution Degree 2 |
|
|
Display |
|
Digital: |
6,000
counts, updates 4 per second |
|
| Bar
graph |
| |
33
segments, updates 32 per second |
|
|
Operating Temperature |
|
|
Storage Temperature |
|
|
Battery type |
| |
9 volt
Alkaline, NEDA 1604A/ IEC 6LR61 |
|
|
Battery Life |
| |
400
hours typical, without backlight |
|
|
Accuracy Specifications |
| DC
millivolts |
|
Range: |
600.0
mV |
|
Resolution: |
0.1 mV |
|
Accuracy: |
± ([%
of reading] + [counts]): 0.5% +
2 |
|
| DC
volts |
|
Range/Resolution: |
6.000 V
/ 0.001 V |
|
Range/Resolution: |
60.00 V
/ 0.01 V |
|
Range/Resolution: |
600.00
V / 0.1 V |
|
Accuracy: |
± ([%
of reading] + [counts]): 0.5% +
2 |
|
| AC
millivolts1
true-rms |
|
Range: |
600.0
mV |
|
Resolution: |
0.1 mV |
|
Accuracy: |
1.0 % +
3 (dc, 45 Hz to 500 Hz)2.0 % + 3
(500 Hz to 1 kHz) |
|
| AC
volts1 true-rms |
|
Range/Resolution: |
6.000 V
/ 0.001 V |
|
Range/Resolution: |
60.00 V
/ 0.01 V |
|
Range/Resolution: |
600.0 V
/ 0.1 V |
|
Accuracy: |
1.0 % +
3 (dc, 45 Hz to 500 Hz)2.0 % + 3
(500 Hz to 1 kHz) |
|
|
Continuity |
|
Range: |
600 Ω |
|
Resolution: |
1 Ω |
|
Accuracy: |
Beeper
on < 20 Ω, off > 250 Ω;
detectsopens or shorts of 500 μs
or longer. |
|
| Ohms |
|
Range/Resolution: |
600.0 Ω
/ 0.1 Ω |
|
Range/Resolution: |
6.000
kΩ / 0.001 kΩ |
|
Range/Resolution: |
60.00
kΩ / 0.01 kΩ |
|
Range/Resolution: |
600.0
kΩ / 0.1 kΩ |
|
Range/Resolution: |
6.000
MΩ / 0.001 MΩ |
|
Accuracy: |
0.9 % +
1 |
|
Range/Resolution: |
40.00
MΩ / 0.01 MΩ |
|
Accuracy: |
5 % + 2 |
|
|
Diode Test |
|
Range/Resolution: |
2.00 V
/ 0.001 V |
|
Accuracy: |
0.9% +
2 |
|
|
Capacitance |
|
Range/Resolution: |
1000 nF
/ 1 nF |
|
Range/Resolution: |
10.00
µF / 0.01 µF |
|
Range/Resolution: |
100.0
µF / 0.1 µF |
|
Range/Resolution: |
9999 µF
/ 1 µF |
|
Range/Resolution: |
100 µF
to 1000 µF |
|
Accuracy: |
1.9% +
2 |
|
Range/Resolution: |
> 1000
µF |
|
Accuracy: |
5% +
20% |
|
| Lo-Z
Capacitance |
|
Range: |
1 nF to
500 µF |
|
Accuracy: |
10% + 2
typical |
|
| AC
amps true-rms (45 Hz to 500Hz) |
|
Range/Resolution: |
6.000 A
/ 0.001 A |
|
Range/Resolution: |
10.00 A
/ 0.01 A |
|
Accuracy: |
1.5% +
3 |
| |
20 A
overload for 30-seconds max |
|
| DC
amps |
|
Range/Resolution: |
6.000 A
/ 0.001 A |
|
Range/Resolution: |
10.00 A
/ 0.01 A |
|
Accuracy: |
1.0% +
3 |
| |
20 A
overload for 30-seconds max |
|
| Hz
(V or A input)2 |
|
Range/Resolution: |
99.99
Hz / 0.01 Hz |
|
Range/Resolution: |
999.9
Hz / 0.01 Hz |
|
Range/Resolution: |
9.999
kHz / 0.001 kHz |
|
Range/Resolution: |
50 kHz
/ 0.01 kHz |
|
Accuracy: |
0.1% +
2 |
|